Right place if you
Have a pump that will not shut off, will not prime, cycles rapidly, or trips a fuse when it starts.
The demand pump is one of the most-replaced parts on an RV — and one of the most often replaced unnecessarily. Find the leak, air path, or strainer issue before you buy another pump.
Active corridor: Montana · Wyoming · Idaho · Washington — case-by-case beyond.
On corridor trips a pump that chatters at 2 a.m. or runs dry after a fill is usually air, a clogged inlet strainer, a slow leak, or freeze damage — not a mysterious “bad pump” from the start.
Have a pump that will not shut off, will not prime, cycles rapidly, or trips a fuse when it starts.
Water tastes bad with good pressure — see sanitizing and filtration. No hot water only — water heater.
Empty tank, air at a loose suction fitting, or a strainer full of debris. Confirm tank water, then work inlet hose and strainer before condemning the pump.
Often still air or a closed valve / empty tank. Listen for cavitation; feel for suction leaks at clamps.
Clear the inlet strainer on a schedule. Grit from unfiltered fills is a top cause of weak flow and early pump wear.
Know your valve positions. Pump on with city pressure fighting it confuses diagnosis.
A pump that will not shut off usually cannot reach cutoff — open faucet, leak (even slow), or a check valve bleeding pressure back. Rapid chatter often points to a waterlogged or missing accumulator, or a pressure switch that has drifted. Fix the pressure path; replacing the pump alone often repeats the symptom.
Demand pumps are 12V loads that spike at start. A weak battery or undersized wiring makes pumps sound sick. Check battery state of charge and fuse rating against the pump label — do not invent amp numbers. Hot connectors and melted fuse holders mean stop and Prefer Text photos.
Strainer clean, hose clamps, fuse check, accumulator inspection, leak hunt with paper towel.
Hidden leaks in walls, repeated pump deaths, electrical heat at terminals, or post-freeze damage. Prefer Text short video of the sound and bay layout.
Many systems run smoother with a working accumulator. A failed one causes chatter that feels like a bad pump.
Usually a valve still open to the pump or a mis-plumbed tee — map your valves before buying parts.
Mounting, rubber feet, and solid bulkheads matter as much as brand marketing.
Trip and labor as below (1-hour min / 30-min increments). Prefer Text for parts unknowns.